ADVANCED VACUUM FURNACE

  • The furnace can reach a 1400 °C max operating temperature, in high vacuum (1E-5 mbar range) or partial pressure of Ar - H2 (up to 10 mbar abs, adjustable from PLC)
  • The vacuum chamber is in stainless steel with Conflat flanges
  • The pumping group is complete with 175000 l/s diffusion pump and cryogenic trap, for ultimate vacuum levels in 1E-6 mbar range
  • The thermal chamber has a circular section, it is entirely metallic (ML+pure moly+steiless steel+alumina), provided with No. 3 independent heating zones along the useful length
  • The furnace is provided with internal gas cooling system, complete with tube&fin heat exchanger, centrifugal fan and motor.

vacuum furnace

MACHINING EQUIPMENTS

  • Machining Centers and milling machines with working strokes up to x=4000, y=1200 and z=2000
  • CNC Turning machines for work pieces up to a diameter of 800 mm and a length of 3000 mm
  • One turning milling machine (turn with auxiliary motorized spindle)
  • Spark erosion machines: drill machine for holes down to 0.3 mm on 150 mm thick copper blocks, EDW machines to cut up to 300 mm of thickness
  • Grinding machine

 

 

WELDING AND CLEANING EQUIPMENTS
  • GTAW and SMAW welding machine (current 300-400 A)
  • MIG and MAG welding machine
  • Ultrasound washing pool with 3 stages (warm bath with detergent, tap water for first rinsing, demineralized water for final rinsing). Useful dimensions: 1500 x 1000 x 1200 (h) mm
VACUUM EQUIPMENTS
  • Two complete dry pumping groups (Varian Try-Scroll forevacuum pump, Varian HT300 turbo pump, Varian Starcell 500 ion pump) with associated pressure gauges
  • Two Residual Gas Analyzer MKS Microvision Plus
  • Backout unit with Gefran temperature controllers up to 15 kw power divided into 10 areas
  • Helium leak detectors: Pfeiffer HLT 265 - Pfeiffer HLT 560
METROLOGY EQUIPMENTS
  • Perthometer Mahr M2; measuring range up to 100 µm and resolution of 12 nm
  • Ultrasound thickness gauge: Panametrics 26XDTL-93-M, measuring range from 0.5 mm up to 500 mm (depending on material), resolution 0.01 mm
  • Height Gauge: Micro-Hite. Measuring range up to 800 mm, resolution of 0.001 mm, accuracy 0.003 mm
  • Angular and linear measurement: Renishaw interferometer. For the linear measurement case the range is up to 40 m and the resolution is 0.001 µm. For the angular measurement the range is up to 10° with a resolution of 0.01 arcsec
  • ZEISS ACCURA 2 measuring center installed

 
 